Electrical Leakage Current Evolution in Photovoltaic Modules: A Coupled Model of Ionic Conduction and Interface Degradation

Authors

  • Ali Kareem Jabbar Department of Cyber Security, College of Computer Science and Information Technology, Wasit University, Iraq
  • Zainab Hussein Abbas Department of Electrical Engineering, College of Engineering, Wasit University, Iraq
  • Muna Mahmood Badan Department of Physics, College of Education for Pure Science, Wasit University, Iraq
  • Hassanein Riyadh Mahmood Department of Renewable Energy Techniques, Technical Institute-Kut, Middle Technical University, Baghdad, Iraq

DOI:

https://doi.org/10.17977/um048v8.i2.2026.53-68

Keywords:

Photovoltaic Module Reliability, Leakage Current, Encapsulant Delamination, Cohesive Zone, Ionic Transport, Potential-Induced Degradation

Abstract

Leakage current in photovoltaic (PV) modules is usually interpreted as a passive measure of encapsulant conductivity. Its paths, however, run through interfaces that degrade mechanically and chemically. This computational study presents a reduced-order model of ionic conduction and interface degradation in which interface debonding is the explicit two-way coupling variable. Moisture ingress, thermo-viscoelastic mismatch stress and hydrolytic loss of adhesion drive a cohesive damage law. Damaged interfaces become thin interphase conduits in parallel with the bulk, glass and condensate-film paths, and the faradaic charge at the frame contact feeds back into damage. A Butler–Volmer closure treats the frame electrode under 1000 V bias. All equations were checked for dimensional and sign consistency, and the constitutive set satisfies a necessary thermodynamic condition. Damp-heat (DH), thermal-cycling (TC) and humidity-freeze (HF) tests of EVA and POE mini-modules were simulated with four nested models and representative, uncalibrated parameters. In the simulations, the DH current accelerates only after the encapsulant is saturated, when hydrolytic weakening lets a debond front advance from the frame; moisture-dependent conductivity alone cannot reproduce this stage. The leakage path then hands over from the bulk to the interface. HF triggers this handover within the first cycles, whereas dry TC damages the edge with little change in current. POE suppresses the mechanism under DH and delays it under HF. In the model, the handover time follows a temperature–humidity acceleration law and is governed almost exclusively by the adhesion-hydrolysis rate. It is proposed, subject to experimental validation, as a mechanism-based metric for encapsulant selection and multi-stress test design.

Downloads

Published

2026-06-08

Issue

Section

Articles